MUGA Railway Station Information and Trains for MUGA

MAHUGARA - MUGA

"gated blood pool imaging", as well as "SYMA scanning" (synchronized multigated acquisition scanning).

This mode of imaging uniquely provides a fluoroscopy#Profusion of names for moving pictures taken with X-rays type of image of the beating heart, and allows the interpreter to determine the efficiency of the individual heart valves and heart chamber. MUGA/Cine scanning represents a robust adjunct to the now more common echocardiogram. Mathematics regarding acquisition of cardiac output (''Q'') is well served by both of these methods as well as other inexpensive models supporting ejection fraction as a product of the heart/myocardium in Systole (medicine). The advantage of a MUGA scan over an echocardiogram

an angiogram is its accuracy. An echocardiogram measures the shortening fraction of the ventricle and is limited by the user's ability. Furthermore, an angiogram is invasive and, often, more expensive. A MUGA scan provides a more accurate representation of cardiac ejection fraction.

The MUGA scan was first introduced in the early 1970s and quickly became accepted as the preferred technique for measurement of left ventricular ejection fraction (LVEF) with a high degree of accuracy. Several early studies demonstrated an excellent correlation of MUGA-derived LVEF with values obtained by cardiac catheterization contrast ventriculography.

MUGA is typically ordered for the following patients:, With known

suspected coronary artery disease, to diagnose the disease and predict outcomes, With lesions in their heart valves, With heart failure, Who have undergone percutaneous transluminal coronary angioplasty, coronary artery bypass graft surgery,

medical therapy, to assess the efficacy of the treatment, With low cardiac output after open-heart surgery, Who are undergoing cardiotoxic drug agents such as in chemotherapy e.g., with doxorubicin

immunotherapy (herceptin), Who have had a cardiac transplant

The MUGA scan is performed by labeling the patient's red blood pool with a radioactive tracer, technetium-99m-pertechnetate (Tc-99m), and measuring radioactivity over the anterior chest as the radioactive blood flows through the large vessels and the heart chambers.

The introduction of the radioactive marker can either take place ''in vivo''

''in vitro''.In the in vivo method, stannous (tin) ions are injected into the patient's bloodstream. A subsequent intravenous injection of the radioactive substance, technetium-99m-pertechnetate, labels the red blood cells ''in vivo''. With an administered activity of about 800 Becquerel, the Effective dose (radiation safety) is about 6 Sievert.

In the ''in vitro'' method, some of the patient's blood is drawn and the stannous ions (in the form of stannous chloride) are injected into the drawn blood. The technetium is subsequently added to the mixture as in the ''in vivo'' method.In both cases, the stannous chloride reduces the technetium ion and prevents it from leaking out of the red blood cells during the procedure.

The ''in vivo'' technique is more convenient for the majority of patients since it is less time-consuming and less costly and more than 80 percent of the injected radionuclide usually binds to red blood cells with this approach. Red blood cell binding of the radioactive tracer is generally more efficient than ''in vitro'' labeling, and it is preferred in patients with indwelling intravenous catheters to decrease the adherence of Tc-99m to the catheter wall and increase the efficiency of blood pool labeling.

The patient is placed under a gamma camera, which detects the low-level 140 keV gamma ray radiation being given off by technetium-99m. As the gamma camera images are acquired, the patient's heart beat is used to 'gate' the acquisition. The final result is a series of images of the heart (usually sixteen), one at each stage of the cardiac cycle.

Depending on the objectives of the test, the doctor may decide to perform either a resting

a stress MUGA. During the resting MUGA, the patient lies stationary, whereas during a stress MUGA, the patient is asked to exercise during the scan. The stress MUGA measures the heart performance during exercise and is usually performed to assess the impact of a suspected coronary artery disease. In some cases, a nitroglycerin MUGA may be performed, where nitroglycerin (a vasodilator) is administered prior to the scan.

The resulting images show that the volumetrically derived blood pools in the chambers of the heart and timed images may be computationally interpreted to calculate the ejection fraction and injection fraction of the heart. The #Massardo method can be used to calculate ventricle volumes. This nuclear medicine scan yields an accurate, inexpensive and easily reproducible means of measuring and monitoring the ejection and injection fractions of the ventricles, which are one of many of the important clinical metrics in assessing global heart performance.

In normal subjects, the left ventricular ejection fraction (LVEF) should be about 50%(range, 50-80%). There should be no area of abnormal wall motion (hypokinesis, akinesis

dyskinesis). Abnormalities in cardiac function may be manifested as a decrease in LVEF and/or the presence of abnormalities in global and regional wall motion. For normal subjects, peak filling rates should be between 2.4 and 3.6 end diastolic volume (EDV) per second, and the time to peak filling rate should be 135-212 ms. (source?)

An uneven distribution of technetium in the heart indicates that the patient has coronary artery disease, a cardiomyopathy,

blood shunting within the heart. Abnormalities in a resting MUGA usually indicate a heart attack, while those that occur during exercise usually indicate ischemia. In a stress MUGA, patients with coronary artery disease may exhibit a decrease in ejection fraction.For a patient that has had a heart attack,

is suspected of having another disease that affects the heart muscle, this scan can help pinpoint the position in the heart that has sustained damage as well as assess the degree of damage. MUGA scans are also used to evaluate heart function prior to and while receiving certain chemotherapies (e.g. doxorubicin (Adriamycin))

immunotherapy (specifically, herceptin) that have a known effect on heart function.

The Massardo method is one of a number of approaches for estimating the volume of the ventricles and thus ultimately the ejection fraction. Recall that a MUGA scan is a nuclear imaging method involving the injection of a radioactive isotope (Technetium-99m) that acquires Gated SPECT 2D images of the heart using a Single-photon emission computed tomography scanner. The pixel values in such an image represent the number of counts (nuclear decays) detected from within that region in a given time interval. The Massardo method enables a 3D volume to be estimated from such a 2D image of decay counts via:

where M is the pixel dimension and r is the ratio of total counts within the ventricle to the number of counts within the brightest (hottest) pixel. The Massardo method relies on two assumptions: (i) the ventricle is spherical and (ii) the radioactivity is homogeneously distributed.

The ejection fraction, E_f , can then be calculated:

where the EDV (end-diastolic volume) is the volume of blood within the ventricle immediately before a contraction and the ESV (end-systolic volume) is the volume of blood remaining in the ventricle at the end of a contraction. The ejection fraction is hence the fraction of the end-diastolic volume that is ejected with each beat.

The Siemens Intevo Single-photon emission computed tomography scanners employ the Massardo method in their MUGA scans. Other methods for estimating ventricular volume exist, but the Massardo method is sufficiently accurate and simple to perform, avoiding the need for blood samples, attenuation corrections

decay corrections.

Define the ratio r as the ratio of counts within the chamber of the heart to the counts in the hottest pixel:

Assuming that the activity is homogeneously distributed, the total count is proportional to the volume. The maximum pixel count is thus proportional to the length of the longest axis perpendicular to the collimator, D_m, times the cross-sectional area of a pixel, M^2. We can thus write:

K M^2 D_m ,

K V_t where V_t is the volume of the ventricle and K is the same constant of proportionality since we are assuming a homogeneous distribution of activity. The Massardo method now makes the simplification that the ventricle is spherical in shape, giving

where D is the diameter of the sphere and is thus equivalent to D_m above. This allows us to express the ratio r as

finally giving the diameter of the ventricle in terms of r, i.e. counts, alone:

From this, the volume of the ventricle in terms of counts alone is simply